Prinsipyo sa Paggawa: Kapag naka-on ang AC contactor, bubuo ng magnetic field ang internal coil, na nagiging sanhi ng pagdikit ng gumagalaw na core ng bakal at ng nakatigil na iron core, na nagtutulak sa contact system na makipag-ugnayan sa nakatigil na contact at pagsasagawa ng circuit. Pagkatapos mawalan ng power ang coil, mawawala ang suction force, at itutulak pataas ng reset spring ang gumagalaw na core ng bakal, na magiging dahilan upang maghiwalay ang mga contact at masira ang circuit.
| MODELO | A (mm) | B (mm) | C (mm) | D (mm) | E (mm) | isang (mm) | b (mm) | Φ (mm) |
| D09~12 | 47 | 76 | 82 | 11 | 133 | 34/35 | 50/60 | 4.5 |
| D18 | 47 | 76 | 87 | 118 | 138 | 34/35 | 50/60 | 4.5 |
| D25 | 57 | 86 | 95 | 126 | 146 | 40 | 48 | 4.5 |
| D32 | 57 | 86 | 100 | 131 | 151 | 40 | 48 | 4.5 |
| D40~65 | 77 | 129 | 116 | 145 | 165 | 40 | 100/110 | 6.5 |
| D80~95 | 87 | 129 | 127 | 175 | 195 | 40 | 100/110 | 6.5 |
| Uri ng Modeloo | 9 | 12 | 18 | 25 | 32 | 40 | 50 | 65 | 80 | 95 | |
| Na-rate ang kasalukuyang gumagana (A) | AC3 | 9 | 12 | 18 | 25 | 32 | 40 | 50 | 65 | 80 | 95 |
| AC4 | 3.5 | 5 | 7.7 | 8.5 | 12 | 18.5 | 24 | 28 | 37 | 44 | |
| Tatlong-phase na motor AC-3 antas (kw) | 220/230V | 2.2 | 3 | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 25 |
| 380/400V | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | |
| 415V | 4 | 5.5 | 9 | 11 | 15 | 22 | 25 | 37 | - | - | |
| 500V | 5.5 | 7.5 | 10 | 15 | 18.5 | 22 | 30 | 37 | - | - | |
| 660/690V | 5.5 | 7.5 | 10 | 15 | 18.5 | 30 | 33 | 37 | 45 | 45 | |
| RatedheatingcurrentIth(A) | 20 | 20 | 30 | 32 | 40 | 50 | 60 | 80 | 125 | 125 | |
| Haba ng kuryente(10000 cycle) | AC3 | 100 | 100 | 100 | 100 | 80 | 80 | 60 | 60 | 60 | 60 |
| AC4 | 20 | 20 | 20 | 20 | 20 | 15 | 15 | 15 | 10 | 10 | |
| Mechanical lifespan(10000 cycle) | 1000 | 1000 | 1000 | 1000 | 800 | 800 | 800 | 800 | 600 | 600 | |
| Modelo ng contact | 3P NO | 3P NC NO | |||||||||
| Model | Rated kasalukuyang (A) | Pangunahing contact | Pantulong na contact | Single-phase load power (kW) | Three-phase load power (kW) |
| CJX2-0910 | 9A | 3HINDI | 1HINDI | 1.8KW | 3.5KW |
| CJX2-0901 | 9A | 3HINDI | 1NC | 1.8KW | 3.5KW |
| CJX2-1210 | 12A | 3HINDI | 1HINDI | 2.5KW | 5KW |
| CJX2-1201 | 12A | 3HINDI | 1NC | 2.5KW | 5KW |
| CJX2-1810 | 18A | 3HINDI | 1HINDI | 3.5KW | 7.5KW |
| CJX2-1801 | 18A | 3HINDI | 1NC | 3.5KW | 7.5KW |
| CJX2-2510 | 25A | 3HINDI | 1HINDI | 5KW | 8.5KW |
| CJX2-2501 | 25A | 3HINDI | 1NC | 5KW | 8.5KW |
| CJX2-3210 | 32A | 3HINDI | 1HINDI | 6KW | 12KW |
| CJX2-3201 | 32A | 3HINDI | 1NC | 6KW | 12KW |
| CJX2-4011 | 40A | 3HINDI | 1HINDI 1NC | 8KW | 18.5KW |
| CJX2-5011 | 50A | 3HINDI | 1HINDI 1NC | 10KW | 24KW |
| CJX2-6511 | 65A | 3HINDI | 1HINDI 1NC | 12.5KW | 28KW |
| CJX2-8011 | 80A | 3HINDI | 1HINDI 1NC | 15.5KW | 37KW |
| CJX2-9511 | 95A | 3HINDI | 1HINDI 1NC | 18.5KW | 44KW |